TY - JOUR
T1 - External counterpulsation reduces beat-to-beat blood pressure variability when augmenting blood pressure and cerebral blood flow in ischemic stroke
AU - Tian, Ge
AU - Xiong, Li
AU - Lin, Wenhua
AU - Han, Jinghao
AU - Chen, Xiangyan
AU - Leung, Thomas Wai Hong
AU - Soo, Yannie Oi Yan
AU - Wong, Lawrence Ka Sing
N1 - Publisher Copyright:
© 2016 Korean Neurological Association.
PY - 2016/7
Y1 - 2016/7
N2 - Background and PurposezzExternal counterpulsation (ECP) is a noninvasive method used to enhance cerebral perfusion by elevating the blood pressure in ischemic stroke. However, the response of the beat-to-beat blood pressure variability (BPV) in ischemic stroke patients during ECP remains unknown. MethodszzWe enrolled recent ischemic stroke patients and healthy controls. Changes in the blood flow velocities in bilateral middle cerebral arteries and the continuous beat-to-beat blood pressure before, during, and after ECP were monitored. Power spectral analysis revealed that the BPV included oscillations at very low frequency (VLF; <0.04 Hz), low frequency (LF; 0.04– 0.15 Hz), and high frequency (HF; 0.15–0.40 Hz), and the total power spectral density (TP; <0.40 Hz) and LF/HF ratio were calculated. ResultszzWe found that ECP significantly increased the systolic and diastolic blood pressures in both stroke patients and controls. ECP decreased markedly the systolic and diastolic BPVs at VLF and LF and the TP, and the diastolic BPV at HF when compared with baseline. The decreases in diastolic and systolic BPV reached 37.56% and 23.20%, respectively, at VLF, 21.15% and 12.19% at LF, 8.76% and 16.59% at HF, and 31.92% and 23.62% for the total TP in stroke patients, which did not differ from those in healthy controls. The change in flow velocity on the contralateral side was positively correlated with the total TP systolic BPV change induced by ECP (r=0.312, p=0.035). ConclusionszzECP reduces the beat-to-beat BPV when increasing the blood pressure and cerebral blood flow velocity in ischemic stroke patients. ECP might be able to improve the clinical outcome by decreasing the beat-to-beat BPV in stroke patients, and this should be explored further in future studies.
AB - Background and PurposezzExternal counterpulsation (ECP) is a noninvasive method used to enhance cerebral perfusion by elevating the blood pressure in ischemic stroke. However, the response of the beat-to-beat blood pressure variability (BPV) in ischemic stroke patients during ECP remains unknown. MethodszzWe enrolled recent ischemic stroke patients and healthy controls. Changes in the blood flow velocities in bilateral middle cerebral arteries and the continuous beat-to-beat blood pressure before, during, and after ECP were monitored. Power spectral analysis revealed that the BPV included oscillations at very low frequency (VLF; <0.04 Hz), low frequency (LF; 0.04– 0.15 Hz), and high frequency (HF; 0.15–0.40 Hz), and the total power spectral density (TP; <0.40 Hz) and LF/HF ratio were calculated. ResultszzWe found that ECP significantly increased the systolic and diastolic blood pressures in both stroke patients and controls. ECP decreased markedly the systolic and diastolic BPVs at VLF and LF and the TP, and the diastolic BPV at HF when compared with baseline. The decreases in diastolic and systolic BPV reached 37.56% and 23.20%, respectively, at VLF, 21.15% and 12.19% at LF, 8.76% and 16.59% at HF, and 31.92% and 23.62% for the total TP in stroke patients, which did not differ from those in healthy controls. The change in flow velocity on the contralateral side was positively correlated with the total TP systolic BPV change induced by ECP (r=0.312, p=0.035). ConclusionszzECP reduces the beat-to-beat BPV when increasing the blood pressure and cerebral blood flow velocity in ischemic stroke patients. ECP might be able to improve the clinical outcome by decreasing the beat-to-beat BPV in stroke patients, and this should be explored further in future studies.
KW - Blood pressure
KW - Blood pressure variability
KW - Cerebral hemodynamics
KW - External counterpulsation
KW - Ischemic stroke
UR - https://www.scopus.com/pages/publications/84978648897
U2 - 10.3988/jcn.2016.12.3.308
DO - 10.3988/jcn.2016.12.3.308
M3 - Article
AN - SCOPUS:84978648897
SN - 1738-6586
VL - 12
SP - 308
EP - 315
JO - Journal of Clinical Neurology (Korea)
JF - Journal of Clinical Neurology (Korea)
IS - 3
ER -