T1 - Review of standards for energy performance of chiller systems serving commercial buildings
AU - Yu, F. W.
AU - Chan, K. T.
AU - Sit, R. K.Y.
AU - Yang, J.
N1 - Funding Information:
The work described in this paper was supported by a grant from the College of Professional and Continuing Education, an affiliate of The Hong Kong Polytechnic University (Project A/C 4.8C.xx.EZ40) and a grant from the Research Grant Council of Hong Kong Special Administrative Region (Project A/C Code: B-Q31R).
Publisher Copyright:
© 2014 Published by Elsevier Ltd.
PY - 2014
Y1 - 2014
N2 - A prescriptive approach is primarily used to establish energy benchmarks for energy systems in buildings. This paper reviews national standards and guidelines for the energy performance of chiller systems which provide cooling energy in commercial buildings but their operation causes the major proportion of electricity consumption in the building sector. The standards reviewed are currently adopted in nine places (in alphabetical order): Australia, California, Canada, China, Chinese Taipei, the EU, Hong Kong, New Zealand and the USA. Under standard rating conditions at full load operation, the minimum required coefficient of performance (COP) ranges from 2.40 to 3.06 for air-cooled chillers and from 3.80 to 6.39 for water-cooled chillers. Some standards state also the COP requirements at part load operation with integrated part load values or seasonal energy efficiency ratios. A classification scheme is provided in the EU and Chinese standards which helps labeling and certifying high efficient chiller products. Criteria for enhancing energy ratings of chiller systems are suggested.
AB - A prescriptive approach is primarily used to establish energy benchmarks for energy systems in buildings. This paper reviews national standards and guidelines for the energy performance of chiller systems which provide cooling energy in commercial buildings but their operation causes the major proportion of electricity consumption in the building sector. The standards reviewed are currently adopted in nine places (in alphabetical order): Australia, California, Canada, China, Chinese Taipei, the EU, Hong Kong, New Zealand and the USA. Under standard rating conditions at full load operation, the minimum required coefficient of performance (COP) ranges from 2.40 to 3.06 for air-cooled chillers and from 3.80 to 6.39 for water-cooled chillers. Some standards state also the COP requirements at part load operation with integrated part load values or seasonal energy efficiency ratios. A classification scheme is provided in the EU and Chinese standards which helps labeling and certifying high efficient chiller products. Criteria for enhancing energy ratings of chiller systems are suggested.
KW - Chiller system
KW - Coefficient of performance
KW - Energy performance standards
UR - http://www.scopus.com/inward/record.url?scp=84922389780&partnerID=8YFLogxK
U2 - 10.1016/j.egypro.2014.12.308
DO - 10.1016/j.egypro.2014.12.308
M3 - Conference article
AN - SCOPUS:84922389780
VL - 61
SP - 2778
EP - 2782
JO - Energy Procedia
JF - Energy Procedia
SN - 1876-6102
T2 - 6th International Conference on Applied Energy, ICAE 2014
Y2 - 30 May 2014 through 2 June 2014
ER -